EasyManua.ls Logo

Siemens SIDOOR AT12 - Overload Protection

Siemens SIDOOR AT12
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electric adjustment and commissioning
Elevator door drive AT12
18 Equipment Manual, 06/2020, A2B00086683-AD
11. If the control signal "CLOSE" is present, the door moves into the "CLOSED" position at initial
speed. If the control signal "OPEN" is present, the door moves into the "OPEN" position at
initial speed.
12. Once the controller has detected the door "OPEN" and "CLOSED" end positions, the
subsequent opening and closing movements proceed at normal speed once again.
Note
Door movements in the "OPEN" and "CLOSE" directions can also be actuated with the learn
run button S501.
13. The door travel values can be matched to the individual door for specific applications.
This requires the Service Tool to be connected.
A PC, on which the Software Kit operating program has been started, can also be connected
via the USB adapter, which is available as a special accessory. Its operation is described in
the Appendix to these instructions.
The following settings can be made:
Function
Adjustment range
Factory setting
Creep distance Open
0... 100 mm
25 mm
Cutter distance Open
0... 100 mm
30 mm
Creep distance Close
0... 100 mm
20 mm
Cutter distance Close
0... 100 mm
40 mm
Maximum speed Open
100... 500 mm/s
500 mm/s
Creep speed Open
30... 90 mm/s
40 mm/s
Cutter speed Open
30... 90 mm/s
60 mm/s
Initial speed Open
30... 90 mm/s
90 mm/s
Maximum speed Close
100... 500 mm/s
250 mm/s
Creep speed Close
30... 90 mm/s
60 mm/s
Cutter speed Close
30... 90 mm/s
40 mm/s
Initial speed Close
30... 90 mm/s
90 mm/s
Nudge speed Close
50... 250 mm/s
150 mm/s
Acceleration ramp OPEN
300... 850 mm/s
2
850 mm/s
2
Braking ramp OPEN
300... 850 mm/s
2
600 mm/s
2
Reversing ramp OPEN/CLOSE
300... 850 mm/s
2
850 mm/s
2
Acceleration ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Braking ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Reversing ramp CLOSE/OPEN
300... 850 mm/s
2
850 mm/s
2
Continuous torque (power) OPEN
0... 1.5 A
1 A
Continuous torque (power) CLOSE
0... 1.5 A
1 A
Cutter press-on torque
0... 5.0 A
2.5 A
Opening force static
70... 120 N
120 N
Closing force static
70... 120 N
110 N
Cutter force static Close
70... 120 N
110 N
Nudge force static Close
70... 120 N
110 N

Other manuals for Siemens SIDOOR AT12