EasyManua.ls Logo

Siemens SIDOOR AT12 - Page 25

Siemens SIDOOR AT12
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electric adjustment and commissioning
Elevator door drive AT12
Manual, 02/2012, A2B00086683A-04
25
12. Once the controller has detected the door "OPEN" and "CLOSED" end positions, the
subsequent opening and closing movements proceed at normal speed once again.
Note
Door movements in the "OPEN" and "CLOSE" directions can also be actuated with the
learn run button S501.
13. The door travel values can be matched to the individual door for specific applications.
This requires the Service Tool to be connected.
A PC, on which the Software Kit operating program has been started, can also be
connected via the USB adapter, which is available as a special accessory. Its operation is
described in the Appendix to these instructions.
The following settings can be made:
Function Adjustment range Factory setting
Creep distance Open 0... 100 mm 25 mm
Cutter distance Open 0... 100 mm 30 mm
Creep distance Close 0... 100 mm 20 mm
Cutter distance Close 0... 100 mm 40 mm
Maximum speed Open 100... 500 mm/s 500 mm/s
Creep speed Open 30... 90 mm/s 40 mm/s
Cutter speed Open 30... 90 mm/s 60 mm/s
Initial speed Open 30... 90 mm/s 90 mm/s
Maximum speed Close 100... 500 mm/s 250 mm/s
Creep speed Close 30... 90 mm/s 60 mm/s
Cutter speed Close 30... 90 mm/s 40 mm/s
Initial speed Close 30... 90 mm/s 90 mm/s
Nudge speed Close 50... 250 mm/s 150 mm/s
Acceleration ramp OPEN 300... 850 mm/s
2
850 mm/s
2
Braking ramp OPEN 300... 850 mm/s
2
600 mm/s
2
Reversing ramp OPEN/CLOSE 300... 850 mm/s
2
850 mm/s
2
Acceleration ramp CLOSE 300... 850 mm/s
2
500 mm/s
2
Braking ramp CLOSE 300... 850 mm/s
2
500 mm/s
2
Reversing ramp CLOSE/OPEN 300... 850 mm/s
2
850 mm/s
2
Continuous torque (power) OPEN 0... 1.5 A 1 A
Continuous torque (power) CLOSE 0... 1.5 A 1 A
Cutter press-on torque 0... 5.0 A 2.5 A
Opening force static 70... 120 N 120 N
Closing force static 70... 120 N 110 N
Cutter force static Close 70... 120 N 110 N
Nudge force static Close 70... 120 N 110 N

Other manuals for Siemens SIDOOR AT12

Related product manuals