Table 5-21 Startup parameter record byte 3
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Telegram type parameter
X X X X X Telegram type
The telegram type on the internal bus is set via bits 0 to 2.
The following coding results:
Default telegram = 0000
b
Mirror telegram = 0001
b
Broadcast = 0010
b
Special telegram = 0011
b
Default = default telegram
0 0 0 Reserved
Table 5-22 Startup parameter record bytes 4 and 5
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Cycle time parameter
0 to 234 (0x00 to 0xEA) Cycle time (high byte)
0 to 96 (0x00 to 0x60) Cycle time (low byte)
The cycle time is given in [ms]. The time range is between 10
and 60000 ms. The cycle time speci󹪝es the minimum time
intervals in which the communication on the internal bus
runs.
The default is 100 ms = 0064
hex
Table 5-23 Startup parameter record bytes 6, 7 and 8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Parameter
0 0 0 0 0 0 0 0 Reserved
Con󹪝guration
The resulting con󹪝guration data is in the GSD 󹪝le (see Table 5-15 GSD 󹪝les (Page 151)).
The structure expected from the PROFINET module is described in the following:
Table 5-24 PROFINET con󹪝guration data
Slot Api Subslot Module
ID
Submodule
ID
Description
0 0 0001
hex
1 1 DAP (ATD430W)
0 0 8000
hex
1 2 Interface
0 0 8001
hex
1 3 Port 1
Controllers
5.5 Relay and 󹪝eldbus interfaces
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 159