Parameter
ID
Name Description
p20039 DCMD_SBIT0_Q47 Level-controlled output; output follows the input inverted
p20043 DCMD_SBIT1_Q51
p20047 DCMD_SBIT2_Q55
p20051 DCMD_SBIT3_Q59
p20055 DCMD_SBIT4_Q63
AND
p20015 DCMD_AND0_Q17 Output is logically ANDed with inputs. a discrepancy analysis of the inputs can be
additionally activated.
p20016 DCMD_AND1_Q18 Output is logically AND-combined with inputs.
(As of V1.10)
p20056 DCMD_AND2_Q64 Output is logically ANDed with inputs. a discrepancy analysis of the inputs can be
additionally activated.
OR
p20017 DCMD_OR0_Q19 Output is logically OR-combined with inputs.
p20018 DCMD_OR1_Q20
NOT
p20019 DCMD_NOT0_Q21 Output is logically NOT-combined with inputs (negation).
p20020 DCMD_NOT1_Q22
XOR
p20021 DCMD_XOR0_Q23 Output is logically exclusively OR-combined with inputs.
FRQ
p20022 DCMD_FRQ0_Q24 Output becomes active as soon as the frequency is detected.
p20023 DCMD_FRQ0_Q25
p20024 DCMD_FRQ1_Q26
p20025 DCMD_FRQ1_Q27
DELAY
p20026 DCMD_OnDELAY_Q28 Output follows positive input signal delayed by the set delay time.
p20027 DCMD_OnDELAY_Q29
COUNTER
p20028 DCMD_COUNTER_Q30 Output is active as long as the counter value is 0.
p20029 DCMD_COUNTER_Q31 Output is active as long as the counter value is 1.
p20030 DCMD_COUNTER_Q32 Output is active as long as the counter value is 2.
COLD-STORAGE FUNCTION (as of V1.12)
p20057 DCMD_CSR_Q65 Output is active as long as the cold storage FBLOCK applies the open signal (see cold
storage function block (as of V1.12)). Replace with "function block" here and in the
following block).
p20058 DCMD_CSR_Q66 Output is active as long as the cold storage FBLOCK applies the cord-operated switch
open signal (see Cold storage function block (as of V1.12) (Page 103)).
p20059 DCMD_CSR_Q67 Output is active as long as the cold storage FBLOCK applies the open signal (see Cold
storage function block (as of V1.12) (Page 103)).
p20060 DCMD_CSR_Q68 Output is active as long as the cold storage FBLOCK applies the stop signal (see Cold
storage function block (as of V1.12) (Page 103)).
Controllers
5.9 Operation and conguration of the control unit
ATD4xxW for industrial applications
200 System Manual, 06/2022, A5E51901827B AA