Note
Vertical mode
When operating vertical applications, the system must be weight-balanced in every position,
e.g. by counterweights or springs.
Modi󹪝cations to the door drive
CAUTION
Loss of liability for defects and material damage
Changes to the door drive lead to the loss of liability for defects and compensation rights, and
the correct function of the door drive is no longer guaranteed.
Observe the following rules:
Do not make any modi󹪝cations to the door drive (motor, control unit, power supply).
Never remove the grounding-type (Schuko) plug of the SIDOOR TRANSFORMER and NT40
(e.g. by cutting). IT IS USED FOR THE REQUIRED DISCONNECTION FROM THE MAINS.
The power supply cord of the power supply (SIDOOR TRANSFORMER, SIDOOR
TRANSFORMER UL or SIDOOR NT 40) cannot be replaced. Scrap the power supply if the
supply cable is damaged.
Notes on maintenance
The SIDOOR system should be included in the maintenance schedule for the system as a whole,
and inspected in the course of the maintenance intervals stated in the schedule.
An inspection should cover the following points:
Visual inspection of the control unit for contamination and damage
Visual inspection of the motor for dirt and damage
Visual and mechanical inspection of the mechanical system, in as far as it is part of the
SIDOOR elevator system. This includes checking the following components:
Attachment of the motor holder, de󹪞ector pulley and mounting bracket
Wear on the toothed belt
Check and remeasure the parameters for the safety-relevant force and energy settings set
during commissioning.
E󹪜ectiveness of safety-relevant functions, e.g. light barriers, emergency stop, two-hand
operation.
Overview of commissioning a door drive
We recommend the following initial commissioning procedure for a door drive:
Connecting and commissioning
10.1 Overview of safety and commissioning
ATD4xxW for industrial applications
294 System Manual, 06/2022, A5E51901827B AA

Table of Contents