A.2.4 SIDOOR M4 L / R
Table A-47 Parameters and setting ranges for SIDOOR M4 L / R
Parameter Parameter ID Unit Pro󹪝le 1* Adjustment range
ATD4xxW
Slow end distance open p3660 mm 30 0 … 100
Slow start distance open p3661 mm 30 0 … 100
Slow start distance close p3662 mm 20 0 … 100
Slow end distance close p3663 mm 40 0 … 100
Maximum speed open p3664 mm/s 600 100 … 800
30 … 800 (as of
V1.03)
Slow end speed open p3665 mm/s 40 30 … 90
Slow start speed open p3666 mm/s 60 30 … 90
Slow initial speed open p3667 mm/s 90 30 … 90
Maximum speed close p3668 mm/s 177 100 … 800
30 … 800 (as of
V1.03)
Slow start speed close p3669 mm/s 60 30 … 90
Slow end speed close p3670 mm/s 40 30 … 90
Slow initial speed close p3671 mm/s 90 30 … 90
NDG speed (reduced) p3672 mm/s 177 50 … 800
30 … 800 (as of
V1.03)
Acceleration ramp open p3673 mm/s
2
1300 300 ... 1400
As of (V1.09): 250 ...
1400
Deceleration ramp open p3674 mm/s
2
600 300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Reversal ramp open/close p3675 mm/s
2
1200 (V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Acceleration ramp close p3676 mm/s
2
500 300 ... 1400
As of (V1.09): 250 ...
1400
Deceleration ramp CLOSE p3677 mm/s
2
500 300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Reversal ramp close/open p3678 mm/s
2
850 300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400