EasyManua.ls Logo

Siemens SIMATIC ET200SP PS 6EP7133-6AB00-0BN0 24 V/5 A - Output Specifications

Siemens SIMATIC ET200SP PS 6EP7133-6AB00-0BN0 24 V/5 A
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
6.2 Output
SIMATIC ET200SP PS
Manual, 03.2018, A5E43207434
29
6.2
Output
6EP7133-6AB00-0BN0 (24 V/5 A)
6EP7133-6AE00-0BN0 (24 V/10 A)
Output
Regulated, isolated DC voltage
Regulated, isolated DC voltage
Rated voltage U
out rated
DC
24 V
24 V
Total tolerance, static ±
3 %
3 %
Static line regulation, approx. ±
0.1 %
0.5 %
Static load regulation, approx. ±
1 %
1 %
Residual ripple
Peak-peak, max.
150 mV 150 mV
Spikes peak-peak, max.
(bandwidth, 200 MHz)
240 mV 240 mV
Adjustment range
22.8 - 28.0 V
22.8 - 28.0 V
Product function output voltage
can be adjusted
Yes Yes
Output voltage setting
Remark
Using a potentiometer
Max. 120 W
Via potentiometer
Max. 240 W
Status display
LED green for 24 V O.K.
LED green for 24 V O.K.
Signaling
Contact rating (isolated): 30 V AC/0.5 A, 60 V DC/0.3 A, 30 V DC/1 A) for 24 V O.K.
Response when switching on/off
Overshoot of U
out
< 720 mV
Overshoot of U
out
< 720 mV
Starting delay, max.
300 ms
300 ms
Start delay, typ.
150 ms
150 ms
Voltage rise
120 V/230 V AC max.
200 ms
200 ms
Voltage rise
120 V/230 V AC typ.
30 ms
30 ms
Rated current I
out rated
5 A 10 A
Current range
Remark
0 - 5 A
60 ... 70 °C derating: 3 % I
out rated
/K
0 - 10 A
60 ... 70 °C derating: 3 % I
out rated
/K
Active power output, typ.
120 W
240 W
Overload capability (Extra Power)
7.5 A for 5 s/min
15 A for 5 s/min
Short-time overload current for a
short circuit when powering up
15 A 30 A
Duration of the overload capability
for an overcurrent condition caused
by a short circuit while powering
up.
Remark
100 ms
once-only
100 ms
once-only
Short-time overload current for a
short circuit in operation, typ.
15 A 30 A

Related product manuals