Programming the Technological Functions
6-65
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Table 6-12 Error list, continued
Error Code (AW-DB, DBW66) Description
HEX
Description
INTDEC
80C4 32964 −32572 Communication error; repeat the job.
80C5 32965 −32571 Distributed I/O not available
80C7 32966 −32570 Job aborted due to restart (warm restart) or cold restart of DP master
8522 34082 −31454 DB too short; the data cannot be read out of the DB (Write request)
8532 34098 −31438 DB no. out of user area
853A 34106 −31430 DB does not exist (Write request)
8544 34116 −31420 Error on the n-th (n > 1) attempt to read a DB following the occurrence
of an error (Write request)
8723 34595 −30941 DB too short. The data cannot be written to the DB (Read request).
8730 34608 −30928 DB write-protected in the CPU. Data cannot be written to the DB (Read
request).
8732 34610 −30926 DB no. out of user area
873A 34618 −30918 DB does not exist (Read request)
8745 34629 −30907 Error on the n-th attempt (n > 1) to write to a DB following the occur-
rence of an error (Read request)
The errors 80A2 to 80A7, as well as 80Cx are temporary, i.e. it is possible that they are eliminated
without your intervention after a certain time of waiting. Messages in the form 7xxx indicate temporary
communication states.