Mounting and connecting the device
3.3 Installing a strain relief
Unified Comfort Panels
38 Operating Instructions, 03/2020, A5E46641217-AA
3. Insert a mounting clip into the cutout provided on the device. Make sure it is in the correct
position; see the section "Positions of the mounting clips (Page 35)".
4. To secure the mounting clip, tighten the grub screw with the slot screwdriver, torque
0.5 Nm.
5. Repeat step 3 and 4 for all mounting clamps until all clamps are fastened.
6. Check the fit of the mounting seal.
3.3 Installing a strain relief
The device's scope of delivery includes a strain relief plate with the required number of fixing
screws.
Note
If the strain relief plate of devices with display diagonal
12" is mounted, then the strain
relief plate projects beyond the outer dimensions of the device. Screw on the strain relief
plate of the devices with display diagonal
12" only after the device has been installed.
The strain relief plate of the devices
with display diagonal 15" can be screwed on before or
after the device has been installed.
Requirement
For mounting of the strain relief plate you need:
The strain relief plate from the scope of delivery
The supplied fixing screws
A torque screwdriver with T20 insert

Table of Contents