Technical specifications
12.1 Technical specifications of the PN/J1939 LINK
SIMATIC PN/J1939 LINK
Operating Instructions, 12/2018, A5E45307564-AA
65
Article number
6BK1623-0AA00-0AA0
2. Interface
Interface type
PROFINET
Physics
Ethernet, 2-port switch, 2*RJ45
Isolated
Yes; 1 500 V AC or 2 250 V DC
Interface types
Number of ports
2
integrated switch
Yes
Protocols
PROFINET IO Device
Yes
Isochronous mode
Isochronous operation (application synchro-
nized up to terminal)
No
Interrupts/diagnostics/status information
Status indicator
Yes
Alarms
Yes
Diagnostics function
Yes
Diagnostics indication LED
RUN LED
Yes
ERROR LED
Yes
MAINT LED
Yes
LINK LED
Yes
RX/TX LED
Yes
Potential separation
Potential separation exists
Yes
Degree and class of protection
Degree of protection acc. to EN 60529
IP20
Standards, approvals, certificates
CE mark Yes
UL approval
Yes
cULus Yes
RCM (formerly C-TICK)
Yes
KC approval Yes
EAC (formerly Gost-R)
Yes
PNO certificate Yes
RoHS conformity
Yes
Marine approval
Germanischer Lloyd (GL)
Yes
Det Norske Veritas (DNV)
Yes

Table of Contents