ET 200U Distributed I/O Station
EWA 4NEB 812 6087-02b
Figures
4-1 ET 200U(DP Siemens): CONFIGURING Screen (1) 4-4. . . . . . . . . . . . . . . . . .
4-2 ET 200U(DP Siemens): CONFIGURING screen (2) 4-5. . . . . . . . . . . . . . . . . .
4-3 ET 200U(DP Siemens): CONFIGURING Screen (3) 4-6. . . . . . . . . . . . . . . . . .
4-4 Example of Process I/O Image with ET 200 4-7. . . . . . . . . . . . . . . . . . . . . . . . .
4-5 Location of the Bank of Switches for Setting the Station Number 4-18. . . . . . .
4-6 SYSTEM START–UP/TEST: MODULE SELECTION Screen 4-21. . . . . . . . . . .
4-7 SYSTEM START–UP/TEST: STATUS/CONTROL Screen 4-22. . . . . . . . . . . . .
4-8 Fault LEDs on the IM 318–B Interface Module 4-26. . . . . . . . . . . . . . . . . . . . . . .
4-9 DIAGNOSTICS: OVERVIEW screen 4-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10 INDIVIDUAL DIAGNOSTICS Screen 4-28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-11 Structure of the Diagnostics Word after Request of the Station Status
(Station Status 1 and Station Status 2) 4-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-12 Structure of the Diagnost. Word after Request of the Station Status
(Station Status 3 and Master Address) 4-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-13 Structure of the Diagnostics Word after Request of the Manufacturer
Identification 4-33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-14 Structure of the Diagnostics Word after Request of Station Diagnostics 4-34.
4-15 Structure of the Diagnostics Word after Request of Module Diagnostics
(Header and Slots 0 to 7) 4-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-16 Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 8 to 15 and 16 to 23) 4-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-17 Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 24 to 31) 4-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tables
4-1 Address IDs for the Modules in an ET 200U(DP Siemens) Station 4-10. . . . . .
4-2 Address IDs for the Modules in an ET 200U(DP Siemens) 4-11. . . . . . . . . . . . .
4-3 Address IDs for the Modules in an ET 200U(DP Siemens) 4-12. . . . . . . . . . . . .
4-4 Address IDs for the Modules in an ET 200U(DP Siemens) 4-13. . . . . . . . . . . . .
4-5 Function of Switch 8 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6 Resetting Outputs with Load Circuit Turned on 4-24. . . . . . . . . . . . . . . . . . . . . . .
4-7 LED Fault Messages from IM 318–B 4-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8 Diagnostics with STEP 5 4-29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9 Structure of Station Diagnostics and Module Diagnostics 4-30. . . . . . . . . . . . . .
ET 200U (DP Siemens): Address Assignment, Starting Up, Diagnosing Faults