Technology instructions
10.3 Motion control
S7-1200 Programmable controller
792 System Manual, V4.2, 09/2016, A5E02486680-AK
16#0049 Configuration error at device Download error-
free configuration to the controller;
enable the axis again with instruction
"MC_Power".
16#004A The technology needs a smaller servo clock. Internal system error.
Check the project for consistency and reload it into
16#004B Device driver not initialized during ramp-up. To enable a technology object, the actuator driver
must be initialized.
Execute the command again later.
Communication with encoder is faulty
16#004C Configuration error at device
• Connect a suitable device.
• Check the device (I/Os).
• Compare the configuration of HW Config and
the technology object.
16#004D The device driver needs a smaller servo clock.
• Connect a suitable device.
• Check the device (I/Os).
• Compare the configuration of HW Config and
the technology object.
16#004E Error in internal communication with the device Check the project for consistency and reload it into
Communication to the device (drive or encoder) is faulty
16#0030 Value has an incorrect number format or is
outside the valid number range
• Download error-free configuration to the con-
troller; enable the axis again with instruction
"MC_Power".
• Correct the incorrect value online;
acknowledge error with instruction "MC_Reset"
and restart the command, if necessary.
The requested logical address is invalid.
• Connect a suitable device.
• Check the device (I/Os).
• Check the topological configuration in HW
Config.
• Compare the configuration of HW Config and
the technology object.
The requested logical output address is invalid.
16#0057 The requested logical output address is invalid.
Value of tag "ControlPanel.Input.TimeOut" is invalid (axis control panel)
16#0030 Value has an incorrect number format or is
outside the valid number range
Correct the value in the tags of the technology
object <Axis name>.ControlPanel.Input.TimeOut.
The value is specified in milliseconds (ms).
Invalid value for the configuration date <Axis name>.Actor.DriveParameter.MaxSpeed
16#0030 Value has an incorrect number format or is
outside the valid number range
Correct the reference value in the drive and in the
configuration of the technology object to Actua-
tor.MaxSpeed/2.
With analog drive connection, correct the refer-
ence value in the drive and in the configuration of
the technology object to Actuator.MaxSpeed/1.17.