Commissioning FM 350-1
6.2 Procedure for assigning parameters
FM 350-1 Counter module
78 Manual, 05/2011, A5E03648639-01
6.2 Procedure for assigning parameters
Check lists
Use the check lists below to check and document the working steps for parameterizing the
FM 350-1.
Table 6- 2 Check list for Count Modes
Working step Options/Procedure ✓
Select encoder
A + B + N
A + B
A
5-V encoder with
symmetrical signals
Monitoring
None
≤200 kHz/≥2.5 μs Max. count frequency
≤20 kHz/≥25 μs
Sinking output
24-V encoder with
asymmetrical signals
Encoder inputs
Sourcing output/push-pull
≤200 kHz/≥2.5 μs Max. count frequency
≤20 kHz/≥25 μs
Sinking output
24 V encoders with pulse
train and direction signal
Encoder inputs
Sourcing output/push-pull
≤200 kHz/≥2.5 μs Max. count frequency
≤20 kHz/≥25 μs
Sinking output
24 V initiator
Encoder inputs
Sourcing output/push-pull
Internal 1 MHz time base
Single
Double
Signal evaluation
Quadruple
Normal Count direction
Inverted
Set operating mode
Continuous counting
Single counting
Periodic counting
0 to +32 bit Set count range
-31 to +31 bit
None
Up
Configuring FM 350-1 in
HW Config
Main count direction
(only with single counting or
periodic counting)
Down