Glossary
CPU 31xC and CPU 31x, Technical data
Glossary-4 Manual, Edition 08/2004, A5E00105475-05
Data, temporary
Temporary data represent local data of a block. They are stored in the L-stack when the
block is executed. After the block has been processed, these data are no longer available.
Default Router
The default router is the router that is used when data must be forwarded to a partner
located within the same subnet.
In STEP 7, the default router is named
Router
. STEP 7 assigns the local IP address to the
default router.
Determinism
See Real Time
Device
Within the context of PROFINET, "device" is the generic term for:
Automation systems,
Field devices (for example, PLC, PC),
Active network components (for example, distributed I/O, valve blocks, drives),
hydraulic devices and
pneumatic devices.
The main characteristic of a device is its integration in PROFINET communication over
Ethernet or PROFIBUS.
The following device types are distinguished based on their attachment to the bus:
PROFINET devices
PROFIBUS devices
See PROFIBUS Device
See PROFINET Device
Device Name
Before an IO device can be addressed by an IO controller, it must have a device name. In
PROFINET, this method was selected because it is simpler to work with names than with
complex IP addresses.
The assignment of a device name for a concrete IO device can be compared with setting the
PROFIBUS address of a DP slave.
When it ships, an IO device does not have a device name. An IO device can only be
addressed by an IO controller, for example for the transfer of project engineering data
(including the IP address) during startup or for user data exchange in cyclic operation, after it
has been assigned a device name with the PG/PC .

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)