Glossary
CPU 31xC and CPU 31x, Technical data
Manual, Edition 08/2004, A5E00105475-05
Glossary-13
suitable basic factory setting which can be customized in STEP 7.
There are static and dynamic parameters
Parameters, dynamic
Unlike static parameters, you can change dynamic module parameters during runtime by
calling an SFC in the user program, e.g. limit values of an analog signal input module.
Parameters, static
Unlike dynamic parameters, static parameters of modules cannot be changed by the user
program. You can only modify these parameters by editing your configuration in STEP 7, for
example, modification of the input delay parameters of a digital signal input module.
PC station
See SIMATIC PC Station
PG
See Programming device
PLC
Programmable controllers (PLCs) are electronic controllers whose function is saved as a
program in the control unit. Therefore, the configuration and wiring of the unit does not
dependend on the PLC function. A programmable logic controller has the structure of a
computer; it consists of a CPU with memory, input/output modules and an internal bus
system. The I/O and the programming language are oriented to control engineering needs.
A PLC in the context of SIMATIC S7 --> is a programmable logic controller.
See CPU
PNO
See PROFIBUS International
Priority class
The S7 CPU operating system provides up to 26 priority classes (or "Program execution
levels"). Specific OBs are assigned to these classes. The priority classes determine which
OBs interrupt other OBs. Multiple OBs of the same priority class do not interrupt each other.
In this case, they are executed sequentially.
Process image
The process image is part of CPU system memory. At the start of cyclic program execution,
the signal states at the input modules are written to the process image of the inputs. At the
end of cyclic program execution, the signal status of the process image of the outputs is
transferred to the output modules.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)