SINAMICS S120 automation components
2.5 Expansion and system components
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
11
2.5 Expansion and system components
Expansion and system components can be used to expand the
SINAMICS S120 base system so that it can perform functions directly in the drive system,
record encoder signals, etc.
Components
For example, the following components are available for SINAMICS S120:
The Terminal Board TB30 can be used to expand the CU320 control unit with
additional digital and analog inputs/outputs.
You require the Sensor Module Cabinet-Mounted SMC10, SMC20, SMC30 when a motor
is to be used without the DRIVE-CLiQ interface or an additional external encoder is
to be attached to the drive system.
The communication board CB10 provides an interface between the control unit
CU320 and a CAN bus system.
The CBE30 communication board provides an interface between the
CU320 control unit and a PROFINET system.
The Terminal Modules TM15, TM17, and TM41 provide additional inputs/outputs with
extended functionality (High Feature) that can be used as an output cam or measuring
input in the technology. Terminal modules are connected directly to the
CU 320 control unit by means of the DRIVE-CLiQ interface.
2.6 Determining the firmware version number
The SINAMICS S120 firmware can generally be determined in various ways.
What is important is whether a configuration already exists in S7T Config.
Determining the firmware version of the SINAMICS S120 from the CF Card
The version number of the SINAMICS S120 is stored on the Compact Flash Card.
The firmware of the SINAMICS S120 must be read from the CF Card when the firmware of
the SINAMICS S120 is not known and no current configuration is available in S7T Config.
The CF Card contains the "CONTENT.txt" file in the root directory. The
"internal version 02.20.28.00" line shows the currently loaded firmware.
The number 02.20.28.00 shown in this example is the current version number
of the firmware.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals