EasyManuals Logo

Siemens SIMATIC S7-300 Module data Product Information

Siemens SIMATIC S7-300 Module data
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Commissioning
3.4 Configuring the drive components
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
39
3.4.3 Manual configuring
Introduction
The manual configuring can only be performed in offline mode of S7T Config.
The components of the drive system that are present must be configured manually using
S7T Config.
Various infeed modules of the SINAMICS
The procedure to be adopted for the manual configuring depends on the SINAMICS infeed.
Three different types of SINAMICS infeeds are available:
Active Line Modules (ALM)
Basic Line Modules (BLM)
Smart Line Modules (SLM)
The same dialogs are used for configuring of Active Line Module and the Basic Line Module;
the configuring of the Smart Line Module differs in some configuration steps.
Note
The configuring with an Active Line Module (ALM) and the configuring of the
Smart Line Module (SLM) is described separately in the following sections.
Each configuring guide contains all required steps. Therefore, select the appropriate
section for your configuration.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)