EasyManuals Logo

Siemens SIMATIC S7-300 Module data Function Manual

Siemens SIMATIC S7-300 Module data
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
03/2013 3 Setting up functions
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-143
Function Description Type
only be seen in a tooltip. permissible,
exception <)
Execution
-
On the client
side
- On the
server
side
With the client-side execution, it is defined that
when the time of the trigger on the PC at the
machine expires, then this signals the server in
order to execute the programmed actions in the
control monitor. All actions can be selected.
Triggering on the server side runs independently
of the machine. The machine can even be
switched-off. Only those actions can be
selected, which do not require any online data
from the machine.
SELECTION
DISPLAY
Reset
- When
closing a
maintenan
ce job
When
executing the
control
monitor
Without a specifically selected reset function, the
next maintenance job is always created again in
the programmed time grid - independent of
closing the maintenance job.
The restart of the trigger time can be set so that
this only starts again after the maintenance job
has been closed.
The next maintenance job is determined by the
time interval set from the time of closing. It
therefore does not make any difference whether
a maintenance job procedure was performed
early or late.
A maintenance job can be initiated by the time
trigger described here - and also by other ORed
event triggers.
The restart of the trigger time is realized by each
trigger of the control monitor used which then
generates the maintenance job.
SELECTION
DISPLAY
Start date A date can be entered individually to start the
intervals.
Once the interval has expired, the trigger is
initiated.
The date is limited to 24 months in the future
and 24 months in the past.
If there are no entries and no common start date
is found, then a message is output to enter a
date.
If participation in common start date is selected,
you cannot make any entries here.
DISPLAY
INPUT
(Date format
with leading
zeros)

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals