03/2013 3 Setting up functions
3.4 Fault services
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
3-145
Function Description Type
Weekly Enter a cycle 'n' in
- Weeks,
by selecting a day of the week from Monday to
Sunday.
DISPLAY
INPUT
SELECTION
(1 to 99 999
minutes or
hours)
Monthly Enter a cycle 'n' in
- Months.
Either by selecting the
- first
- second
- third or
- fourth
day of the week from Monday to Sunday in the
month
- OR -
one day from 1 to 31 in the month (then, without
a weekday).
DISPLAY
INPUT
SELECTION
(1 to 99 999
minutes or
hours)
Duration of the interval
Last execution
Undefined
There is no restriction pre-selected regarding a
last initiation.
If you deselect "Undefined", you need to select a
date for the last execution.
DISPLAY
SELECTION
(Toggle)
- On the
You can only make an entry if undefined is
deselected for the last execution.
The can only specify a date for the last
execution via the calendar selection function.
DISPLAY
SELECTION
Each trigger can be assigned a label, which determines its behavior at the central
start date for maintenance.
See also Section: Editing the master data of a machine and the general description
of the trigger in Section: Setting up functions.
Options:
If a label has been set and a start date, which has not yet been reached, has
been configured in the overview of the control monitors, the trigger will not be
initiated.
If the date has been reached or is in the past, the interval starts and a trigger
is initiated at the end of the interval.
If a start date has not been configured, or the label has not been set, the
trigger will be initiated at the end of the interval according to the conditions set
for it.
Notice
The starting time and start date are not the time of the first trigger, but the start of
the interval at the end of which the trigger takes place.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)