2 Machine information 03/2013
2.2 Variable monitors – time Series – measurements and measurement series
© Siemens AG 2006-2013 All Rights Reserved
2-52 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
2.2.7 Variable monitors
Function description
Variable monitors enable the recording in the control of changes over time of any
status data. The variable monitors are essentially for long-term recording in slow
data recording cycles (as opposed to the PLC trace).
Variables can be recorded in a variable monitor. Depending on the variable type,
the recording cycle is not absolutely synchronous. The PLC variables recorded can
be from the PLC environment: inputs, outputs, counters, flags, and any data
addresses in PLC blocks. From the NC environment, they can be machine data,
setting data, system variables and others.
The variables recorded can be scaled and assigned freely definable units.
Individual variables of a variable monitor can be identified as counting variables
(e.g. workpiece counters). These variables can be used in the configuration of
interval triggers to trigger recurring actions after a certain number of counting units
have elapsed. Counting variables are counted up monotonically. Resetting of the
variables in the control is compensated for by the system because the count is
resumed on the basis of the last value before reset.
Limit values can be configured for each variable for automatic monitoring of the
state. Actions can be triggered when limit values are violated. This is the same as
described for the control monitors.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)