Commissioning
3.4 Configuring the drive components
Connection of the SINAMICS S120 to the Technology CPU
62 Product Information, 09/2011, A5E00480378-04
9. Now perform the internal wiring of the Ready to run signal using the BICO engineering of
the SINAMICS S120. Click the blue icon for the wiring of the binector and select
"Control unit" or "Further interconnections". The dialog for the possible interconnections
of the individual components opens. Select, for example, the "r722 Bit0 CO/BO
parameter here: CU digital inputs, status: DI 0 X122.1…." on the control unit and
click the "OK" button to confirm the selection. Click the "Next" button to close the
BICO wiring.