105013 Standard UMS cannot be loaded POWER ON
Power up
The MMC system boots up without NCK
The Siemens configuration file NCMEMCFG.020 does not exist. When transferring the standard configuration, an
error occurred or the NCK signals an error in memory configuration.
New system software
105014 Operator panel initialization failed POWER ON
Power up
No power up of MMC
Operator panel cannot be initialized
Check whether serial driver has been loaded, POWER ON
105015 There is no directory for temporary files! POWER ON
Power up
No power up of MMC
There is no directory for temporary files in the data management
Reload MMC software
105017 Boot file ... cannot be loaded OK softkey
When loading from NCK, PLC or SIMODRIVE 611–D
–
–
–
Applies up to SW 4
105017 System file not loaded Acknowledgement key
While loading NCK/PLC or SIMODRIVE 611D.
MMC powers up without NCK and message 105002 appears.
No file operation (read, position, ...) could be performed on system file ... or an error has occurred during transmis-
sion. Message 105011 – reference to incorrect file operation – also missing during file operation.
Notify system service.
Applies as from SW 5
105018 Error in memory configuration ³ standard configuration loaded OK softkey
–
Boot with standard configuration
Memory configuration could not be loaded and initiated. Error in the customer configuration.
Create new customer configuration
105020 NCK crash ... 10 following lines POWER ON
Permanent
The register dump for alarms 105031 – 105039 is written into the log
Alarm 105005 has also been output ––> see alarm 105005
NCK has crashed and has saved register dump
Report register dump from alarm log to Siemens Service, POWER ON
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Note
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description