Expert functions
5.8 Activating a brake
Connecting the SIMODRIVE 611U to the Technology CPU
88 Product Information, 03/2008, A5E00272066-05
Fast stop (OFF3):
The drive is braked at the fast stop ramp (emergency stop). When the speed threshold is
reached, the holding brake is enabled which disables the pulse enable once the brake
closing time has elapsed.
6SHHGVHWSRLQW
$FWXDOVSHHG
Q
+ROGLQJEUDNH
+ROGLQJEUDNH
RSHQ
6ZLWFKLQJ2Q,QKLELWHG
%UDNHFORVLQJWLPH
2))
t
t
t
t
t