Parameter list 02.00
11-84 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
n012
(2012)
S00
Connector/binector converter 3 (bit field 3) FB 12
As for n010
Ind: None
Type: V2
P052 = 3
Binector/connector converters
n013
(2013)
S00
Binector/connector converter 1 (bit field 4) FB 13
Displays the status of the bits in the bit field on the bars of the 7-segment
display
3210
4
5
6
7
89101112131415
Segment alight: Bit = log. "1" state
Segment dark: Bit = log. "0" state
Ind: None
Type: V2
P052 = 3
n014
(2014)
S00
Binector/connector converter 2 (bit field 5) FB 14
As for n013
Ind: None
Type: V2
P052 = 3
n015
(2015)
S00
Binector/connector converter 3 (bit field 6) FB 15
As for n013
Ind: None
Type: V2
P052 = 3
Technology controller
n016
(2016)
S00
Actual value display FB 260
-200.0 to 199.9
[%]
0.1
Ind: None
Type: I2
P052 = 3
n017
(2017)
S00
Setpoint display FB 260
-200.0 to 199.9
[%]
0.1
Ind: None
Type: I2
P052 = 3
n018
(2018)
S00
Display of effective Kp factor FB 260
0.00 to 30.00
0.01
Ind: None
Type: O2
P052 = 3
n019
(2019)
S00
Display of technology controller output FB 260
-200.0 to 199.9
[%]
0.1
Ind: None
Type: I2
P052 = 3
Velocity/speed calculator
n020
(2020)
S00
Display of actual speed FB 261
-200.0 to 199.9
[%]
0.1
Ind: None
Type: I2
P052 = 3
n021
(2021)
S00
Display of actual velocity FB 261
-32.768 to 32767
[m/s]
0.001
Ind: None
Type: I2
P052 = 3
n022
(2022)
S00
Display of setpoint velocity FB 261
-32.768 to 32767
[m/s]
0.001
Ind: None
Type: I2
P052 = 3
n023
(2023)
S00
Display of setpoint speed FB 261
-200.0 to 199.9
[%]
0.1
Ind: None
Type: I2
P052 = 3
11.49 Settable fixed values [SW 1.8 and later]
Only active with optional technology software S00
U099
(2099)
S00
Fixed value [SW 1.8 and later]
The values set in Index .001 to .100 are connected to connectors K9501 to
K9600
-199.99 to 199.99
[%]
0.01%
Ind: 100
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line