02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-127
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
11.68 Definition of the function of the relay output at terminals 109 / 110
U619
(2619)
*
BDS
Source for the relay output "line contactor ON" (terminals 109 / 110)
[SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
124 = Main contactor EIN
All binector numbers
1
Ind: 2
FS=124
Type: L2
P052 = 3
P051 = 40
off-line
11.69 Starting pulse – Speed controller
(See also Chapter 8 Function Diagram Sheet G150)
U651
(2651)
FDS
Starting pulse (integrator setting value for the speed controller) [SW 1.7
and later]
-100.00 to 100.00
[%]
0.01%
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
U652
(2652)
FDS
Multiplier for starting pulse with neg. setpoint [SW 1.7 and later]
if the starting pulse acc. to U651 is also used for pos. setpoint
0.00 to 100.00
[%]
0.01%
Ind: 4
FS=50.00
Type: O2
P052 = 3
P051 = 40
on-line
U653
(2653)
FDS
Starting pulse with neg. setpoint [SW 1.7 and later]
-100.00 to 100.00
[%]
0.01%
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
U655
(2655)
*
Source for Starting pulse [SW 1.7 and later]
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind: None
FS=451
Type: L2
P052 = 3
P051 = 40
off-line
U656
(2656)
*
Source for starting pulse with neg. setpoint [SW 1.7 and later]
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind: None
FS=452
Type: L2
P052 = 3
P051 = 40
off-line
U657
(2657)
*
BDS
Source for switchover starting pulse for pos./neg. setp.[SW 1.7 and
later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
11.70 Evaluation of a 4-step master switch for cranes
(See also Chapter 8 Function Diagram Sheet G125)
U660
(2660)
*
Source for travel command 1 [SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U661
(2661)
*
Source for travel command 2 [SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U662
(2662)
*
Source for switchover to setpoint step S2 [SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U663
(2663)
*
Source for switchover to setpoint step S3 [SW 1.7 and later]
0 = Binector B0000
1 = Binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
off-line