EasyManua.ls Logo

Siemens SIMOREG DC Master 6RA7018-6DS22 - Page 545

Siemens SIMOREG DC Master 6RA7018-6DS22
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
02.00 Connectors and binectors
SIEMENS AG 6RX1700-0AD76 12-5
SIMOREG DC Master Operating Instructions
Connector Description Normalization Function
diag., Sheet
K0202
Inching setpoint
16384
=
100%
G129
K0203
Oscillation setpoint
16384
=
100%
G128
K0204
Fixed setpoint
16384
=
100%
G127
K0206
Crawling setpoint: Output value of function block
16384
=
100%
G130
K0207
Inching setpoint: Output value of function block
16384
=
100%
G129
K0208
Forcing, oscillation: Output value of function block
16384
=
100%
G128
K0209
Fixed setpoint: Output value of function block
16384
=
100%
G127
Motorized potentiometer
K0240
Motorized potentiometer output (setpoint from potentiometer)
16384
=
100%
G126
K0241
dy/dt (rise in ramp-function generator output in time period set in P542 +
P465)
16384
=
100%
G126
K0242
Ramp-function generator input in motorized potentiometer (setpoint)
16384
=
100%
G126
Closed-loop field current control, field gating unit
K0250
Firing angle (field)
16384
=
0
=
90°
-16384
=
180°
G166
K0251
Firing angle (field) before limitation
16384
=
0
=
90°
-16384
=
180°
G166
K0252
Precontrol value + field current controller output
(gating unit input)
16384
=
0
=
90°
-16384
=
180°
G166
K0260
Current controller output (field)
16384
=
100%
G166
K0261
Current controller P component (field)
16384
=
100%
G166
K0262
Current controller I component (field)
16384
=
100%
G166
K0263
Current controller setpoint/actual value deviation (field)
16384
=
100%
G166
K0265
Actual value at field current controller input
16384
=
100%
G166
K0266
Absolute internal actual current value (field)
16384
=
100%
G166
K0268
Setpoint at field current controller input
16384
=
100%
G166
K0271
Precontrol output (field)
16384
=
100%
G166
Closed-loop EMF control
K0273
Lowest positive current limit (field)
16384
=
100%
G165
K0274
Lowest negative current limit (field)
16384
=
100%
G165
K0275
Current controller setpoint (field) before standstill field
16384
=
100%
G165
K0276
Current controller setpoint (field) before limitation
16384
=
100%
G165
K0277
Current controller setpoint (field) before summing stage at limiter input
16384
=
100%
G165
K0278
Precontrol value + EMF controller output
16384
=
100%
G165
K0280
EMF controller output
16384
=
100%
G165
K0281
P component of EMF controller
16384
=
100%
G165
K0282
I component of EMF controller
16384
=
100%
G165
K0283
EMF controller, setpoint/actual value deviation
16384
=
100%
G165
K0284
EMF controller, setpoint/actual value deviation after droop
16384
=
100%
G165
K0285
EMF controller actual value
16384
=
P078.001
*
32
π
G165
K0286
Absolute value of actual EMF
16384
=
P078.001
*
32
π
G165
K0287
Signed actual EMF value
16384
=
P078.001
*
32
π
G165

Table of Contents