Connections 02.00
6-14 Siemens AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
6.1.2.4 List of recommended RI suppression filters
Rated current
RI suppres-
sion
filter (A)
RI suppression filter
Order number
Terminal
cross-
section
(mm²)
Weight
(kg)
Dimensions
HxWxD
(mm)
12 6SE7021-0ES87-0FB0 10*) 2.2 215x90x81
18 6SE7021-8ES87-0FB0 10*) 2.2 215x90x81
36 6SE7023-4ES87-0FB0 25 3.7 245x101x86
80 6SE7027-2ES87-0FB0 50 9.5 308x141x141
120 6SE7031-0ES87-0FA0 50 10 348x171x141
180 6SE7031-8ES87-0FA0 95 13 404x171x141
500 6SE7033-7ES87-0FA0 Connecting
lug
49 590x305x154
1000 6SE7041-0ES87-0FA0 Connecting
lug
90 840x465x204
1600 6SE7041-6ES87-0FA0 Connecting
lug
130 870x465x204
*) RI suppression filters generate discharge currents. VDE 0160 specifies a PE connection with 10
mm².
In the case of converters with 3-phase connection, the line current (filter current) equals the DC
current x 0.82.
In the case of converters with 2-phase connection, two phase are connected to the three-phase RI
suppression filter. In this instance, the line current is equal to the DC current.
Important technical data of RI suppression filters:
Rated supply voltage 3AC 380-460 V (± 15%)
Rated frequency 50/60 Hz (± 6%)
Operating temperature
0° C to +40° C
Degree of protection IP20 (EN60529)
IP00 with 500 A and above
For further technical data about RI suppression filters, please refer to the Operating Instructions:
SIMOVERT Master Drives RI Suppression Filters EMC Filters, Order number: 6SE7087-6CX87-
0FB0.