EasyManua.ls Logo

Siemens Simotics HV C 1NA14544WA600AG0-Z - Decommissioning the machine

Siemens Simotics HV C 1NA14544WA600AG0-Z
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
See also
Commissioning (Page 59)
8.6.3 Measuring the insulation resistance after an extended stoppage
Measuring the insulation resistance and polarization index (PI) provides information on the
condition of the machine. It is therefore important to check the insulation resistance and the
polarization index at the following times:
Before starting up a machine for the first time
After an extended period in storage or downtime
Within the scope of maintenance work
The following information is provided regarding the state of the winding insulation:
Is the winding head insulation conductively contaminated?
Has the winding insulation absorbed moisture?
As such, you can determine whether the machine needs commissioning or any necessary
measures such as cleaning and/or drying the winding:
Can the machine be put into operation?
Must the windings be cleaned or dried?
Detailed information on testing and the limit values can be found here:
"Testing the insulation resistance and polarization index" (Page 35)
8.7 Decommissioning the machine
Record the decommissioning steps. This log will be useful upon recommissioning.
If the machine is going to be out of service for longer than six months, then take the
necessary measures for preservation and storage. Otherwise, the machine could be
damaged as a result of not being operated.
See also
Protection against corrosion (Page 31)
Storage (Page 28)
8.8 Re-commissioning the machine
When you re-commission the machine, proceed as follows:
Study the record made when the machine was decommissioned, and reverse the measures
that were taken for conservation and storage.
Perform the measures listed in the "Commissioning" section.
Operation
8.7 Decommissioning the machine
SIMOTICS HV C 1NA14544WA600AG0-Z
Operating Instructions 06/2018 69

Table of Contents

Related product manuals