9.2.4.2 Remove V ring
Depending on the particular version, there is a V ring. It must be replaced if unusual amounts
of grease escape from the roller bearing or the V ring is visibly damaged.
Figure 9-1 Remove the V ring
1. Mark the components so that they can be correctly assembled.
2. Remove the V ring with the bearing cap – or by using a suitable tool from the shaft.
Removing the protective ring for degree of protection IP56 (non-heavy-sea)
The V ring for the outer bearing seal is fitted with a protective ring for the degree of protection
IP56 (non-heavy-sea). The protective ring does not have to be removed for disassembling the
bearing bush.
Remove the protective ring together with the V ring and the outer bearing cover or end shield
from the shaft.
See also
Install the V ring (Page 108)
9.2.4.3 Removing the labyrinth sealing ring
Note
For the "Increased degree of protection" option, the machine is equipped with a labyrinth
sealing ring on the drive side and the non-drive side.
Before uninstalling the roller bearing, the labyrinth sealing ring must be removed.
The labyrinth sealing ring is fixed with three grub screws that are separably secured with
adhesive such as Loctite 243.
Maintenance
9.2 Corrective Maintenance
SIMOTICS TN Series N-compact 1LH8
106 Operating Instructions 06/2017