EasyManua.ls Logo

Siemens SIMOTICS TN N-compact 1LH8 - Mechanical Faults; Table 8-2 Mechanical Faults on Water-Cooled Machines

Siemens SIMOTICS TN N-compact 1LH8
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.10.3 Mechanical faults
The following table shows the possible causes of and remedial measures for mechanical faults.
Table 8-2 Mechanical faults on water-cooled machines
↓ Grinding noise
↓ Overheating
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults Remedial measures
X Rotating parts are grinding Establish the cause and realign the parts.
X Reduced cooling Check the water flow.
Consult the manufacturing plant if necessary.
X Rotor not balanced Decouple the rotor and then rebalance it.
X Rotor out of true, shaft bent Please consult the manufacturer.
X X Poor alignment Align the machine set and check the coupling
.
X Coupled machine not balanced Rebalance the coupled machine.
X Shocks from coupled machine Investigate the coupled machine.
X X Fault originating from gearing Fix the gearing.
X X Resonance of the overall system comprising ma‐
chine and foundation
Reinforce the foundation after consultation with the
manufacturer.
X X Changes in foundation Determine the cause and rectify it. Realign the ma‐
chine.
Note any changes taking place during warm up
Operation
8.10 faults
SIMOTICS TN Series N-compact 1LH8
Operating Instructions 06/2017 89