Connecting
3.3 Installing the Power Module
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
35
Dimensions and drilling patterns for the PM240 Power Modules
:LGWK
+HLJKW
:LGWK
+HLJKW
:LGWK
+HLJKW
E
D
E
D
)6$
)6%)6)
EE
DF
F
)6*;
Figure 3-1 PM240 dimension drawing
Table 3- 1 Dimensions for the PM240 Power Modules, IP20
PM240 Power Dimensions Clearances
IP20 kW Height Width Depth a b c top bottom lateral
mm
inch
173
6,81
73
2,87
145
5,71
160
6,30
36,5
1,44
100
3,94
100
3,94
30*
1,18*
FSA 0,37 … 1,5
Fixing: M4 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
270
10,63
153
6,02
165
6,5
258
10,16
133
5,24
100
3,94
100
3,94
40*
1,57*
FSB 2,2 … 4
Fixing: M4 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
334
13,15
189
7,44
185
7,28
323
12,72
167
6,57
125
4,92
125
4,92
50*
1,97*
FSC 7,5 … 15
Fixing: M5 screws, Torque: 2.5 Nm / 22.1 lbf.in
mm
inch
419
16,50
275
10,83
204
8,03
325
12,8
235
9,25
11
0,4
300
11,81
300
11,81
0
0
FSD
without
filter
18,5 … 30
Fixing: M6 screws, Torque: 6 Nm / 53 lbf.in
mm
inch
512
20,16
275
10,83
204
8,03
419
16,50
235
9,25
11
0,4
300
11,81
300
11,81
0
0
FSD with
filter,
Class A
18,5 … 30
Fixing: M6 screws, Torque: 6 Nm / 53 lbf.in