EasyManua.ls Logo

Siemens SINAMICS G120 CU240E-2 - Page 38

Siemens SINAMICS G120 CU240E-2
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting
3.3 Installing the Power Module
Inverter with CU240B-2 and CU240E-2 Control Units
38 Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
:LGWK
DD
F
H G
&XWRXWLQWKH
FRQWUROFDELQHW
IRUWKHKHDW
VLQN
E
+HLJKW
G
Figure 3-3 Dimensions and drilling pattern, PM240-2 PT
Table 3- 3 Power Module PM240-2, push-through
PM240-2 Power Dimensions Clearances
PT kW Heigh
t
Width Depth a b c d e top bottom lateral
mm
inch
226
8,90
126
4,96
165
6,50
103
4,06
106
4,17
188
7,04
9
0,35
88
3,46
100
3,94
100
3,94
0
0
FSA
without /
with filter
2,2 … 3
Fixing: M4 screws, Torque: 2.5 Nm / 22.1 lbf.in