Commissioning
4.3 Frequently required parameters
CU250S-2 Control Units
22 Compact Operating Instructions, 05/2014, A5E32899990B AB
Description files for fieldbuses
The description files are electronic device data sheets which contain all the required
information of a higher-level controller. You can configure and operate the inverter on a
fieldbus with the appropriate description file.
Generic Station
Description (GSD) for
PROFIBUS
Internet:
(http://support.automati
on.siemens.com/WW/vi
GSD and GSDML are saved in the inverter. The
inverter writes its GSD or GSDML to the memory
card once you insert this card in the inverter and
set p0804 to 12. You can then transfer the file to
your programming device or PC using the
memory card.
GSD Markup Language
(GSDML) for
PROFINET
Internet:
(http://support.automati
on.siemens.com/WW/vi
Electronic Data Sheet
(EDS) for CANopen
Internet:
(http://support.automati
on.siemens.com/WW/vi
---
--- Further information can be found in the operating
Frequently required parameters
p0015
Set defaults for inputs and outputs via a macro Terminal blocks (Page 10).
Control Unit firmware version
p0100
0: Europe 50 [Hz]
1: NEMA motor (60 Hz, US units)
2: NEMA motor (60 Hz, SI units)
Rated motor power [kW] or [hp]
Rated motor frequency [Hz]
p0601
Motor temperature sensor type
0: No sensor (factory setting)
1: PTC (→ p0604)
2: KTY84 (→ P0604)
Terminal 15 T2 motor (-)
Motor ambient temperature during commissioning [° C]