Parameters
List of Parameters
1-118
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines fixed frequency setpoint 15.
Note: See parameter P1001 (fixed frequency 1).
Description: Fixed frequencies can be selected in two different modes.
Parameter P1016 defines the mode.
Values: 1: Direct selection
2: Binary selection
Note: See P1001 (fixed frequency 1) for description of how to use fixed frequencies.
Description: Defines origin of fixed frequency selection.
Dependency: Accessible only if P0701 - P070x = 99 (function of digital inputs = BICO)
When Standard Telegram 350 and PROFIBUS selected (P0700 = 6, P0922 = 350), parameter cannot be changed.
Description: Defines origin of fixed frequency selection.
Dependency: Accessible only if P0701 - P070x = 99 (function of digital inputs = BICO)
When Standard Telegram 350 and PROFIBUS selected (P0700 = 6, P0922 = 350), parameter cannot be changed.
Description: Defines origin of fixed frequency selection.
Dependency: Accessible only if P0701 - P070x = 99 (function of digital inputs = BICO)
When Standard Telegram 350 and PROFIBUS selected (P0700 = 6, P0922 = 350), parameter cannot be changed.
p1015[0...2] Fixed frequency 15 / Fixed frequency 15
Access level: 2 P-Group: Setpoints Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
-650.00 [Hz] 650.00 [Hz] 65.00 [Hz]
p1016[0...2] Fixed frequency mode / FF mode
Access level: 2 P-Group: Setpoints Data type: Unsigned16
Quick comm. NO Active: NO Data set: DDS
Can be changed: T
Min Max Factory setting
1 2 1
p1020[0...2] BI: Fixed freq. selection Bit 0 / FF sel. Bit 0
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 722.3
p1021[0...2] BI: Fixed freq. selection Bit 1 / FF sel. Bit 1
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 722.4
p1022[0...2] BI: Fixed freq. selection Bit 2 / FF sel. Bit 2
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 722.5