List of Parameters
Parameters
1-121
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240E
CU240S
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 19.14
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240S DP
CU240S DP-F
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 2090.14
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240S PN Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 8890.14