Siemens Sinamics G120 Series - p1325[0...2] Programmable V;f volt. coord. 3; V;f volt. coord. 3; p1330[0...2] CI: Voltage setpoint; Voltage setp.; p1333[0...2] Start frequency for FCC; Start freq for FCC; p1334[0...2] Slip compensation activation range; Slip c. act. range

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-161
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: See P1320 (programmable V/f freq. coord. 1).
Description: BICO parameter for selecting source of voltage setpoint for independent V/f control (P1300 = 19).
Description: Defines start frequency at which FCC (flux current control) is enabled as [%] of rated motor frequency (P0310).
Notice: If this value is too low, the system may become unstable.
Description: To set the frequency activation range for slip compensation. The percentage value of P1334 refers to the motor
rated frequency P0310.
The upper threshold will always stay 4 % above P1334.
Dependency: Slip compensation (P1335) active.
Note: See parameter P1335.
The starting frequency of the slip compensation is P1334 * P0310.
p1325[0...2] Programmable V/f volt. coord. 3 / V/f volt. coord. 3
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [V] 3000.0 [V] 0.0 [V]
p1330[0...2] CI: Voltage setpoint / Voltage setp.
Access level: 3 P-Group: Closed-loop control Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
p1333[0...2] Start frequency for FCC / Start freq for FCC
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [%] 100.0 [%] 10.0 [%]
p1334[0...2] Slip compensation activation range / Slip c. act. range
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
1.0 [%] 20.0 [%] 6.0 [%]
P1334 P1334+4 %
P1335
100 %
%
Range of slip compensation :
without
slip compensation
with
slip compensation
f
f
N
set
f
f
N
out
f
f
N
out
P1334
P1334+4 %