Description: Selects torque setpoint source.
The selection of settings is detailed in the following table of values, in which the main setpoint is given by the least
significant digit (right-hand position) and the additional setpoint is given by the most significant digit (left-hand posi-
tion). Single digits denote main setpoints that have no additional setpoint.
Values: 0: No main setpoint
2: Analog setpoint
4: USS on RS232
6: Fieldbus
7: Analog setpoint 2
20: No main setpoint + Analog setpoint
22: Analog setpoint + Analog setpoint
24: USS on RS232 + Analog setpoint
26: Fieldbus + Analog setpoint
27: Analog setpoint 2 + Analog setpoint
40: No main setpoint + USS on RS232
42: Analog setpoint + USS on RS232
44: USS on RS232 + USS on RS232
46: Fieldbus + USS on RS232
47: Analog setpoint 2 + USS on RS232
60: No main setpoint + Fieldbus
62: Analog setpoint + Fieldbus
64: USS on RS232 + Fieldbus
66: Fieldbus + Fieldbus
67: Analog setpoint 2 + Fieldbus
70: No main setpoint + Analog setpoint 2
72: Analog setpoint + Analog setpoint 2
74: USS on RS232 + Analog setpoint 2
76: Fieldbus + Analog setpoint 2
77: Analog setpoint 2 + Analog setpoint 2
Caution: Changing this parameter sets (to default) all settings on item selected. These are the following parameters:
P1503, P1511
p1500[0...2] Selection of torque setpoint / Torque setp. sel.
CU240S DP
CU240S DP-F
CU240S PN
Access level: 2 P-Group: Closed-loop control Data type: Unsigned16
Quick comm. YES Active: NO Data set: CDS
Can be changed: C, T
Min Max Factory setting
0 77 0