List of Parameters
Parameters
1-183
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Enables thermal adaptation of stator and rotor resistance to reduce torque errors in speed/torque regulation with
speed sensor, or speed errors in speed/torque regulation without speed sensor.
Note: Only stator resistance adaptation is carried out for synchronous motors.
Description: Enters Rs-adaptation controller integral time.
Description: Displays stator resistance adaptation from controller in [%] relative to rated motor resistance.
Note: The rated motor resistance is given by the formula:
Description: Enters Xm-adaptation controller integral time.
Description: Displays main reactance adaptation from controller in [%] relative to rated impedance.
Note: The rated motor resistance is given by the formula:
p1780[0...2] Control word of Rs/Rr-adaption / CtrlWd Rs/Rr adapt
Access level: 3 P-Group: Closed-loop control Data type: Unsigned16
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
- - 0111 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable thermal Rs/Rr-adapt. Yes No -
01 Enable observer Rs-adapt. Yes No -
02 Enable observer Xm-adapt. Yes No -
p1781[0...2] Tn of Rs-adaption / Tn of Rs-adaption
Access level: 4 P-Group: Closed-loop control Data type: Unsigned16
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
10 [ms] 2000 [ms] 100 [ms]
r1782 CO: Output of Rs-adaptation / Output Rs-adaption
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [%] Data set: -
% 100 <=>
0305p3
0304p
I 3
V
Z
N
N
N
=
=
Rated motor impedance:
p1786[0...2] Tn of Xm-adaption / Tn of Xm-adaption
Access level: 4 P-Group: Closed-loop control Data type: Unsigned16
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
10 [ms] 2000 [ms] 100 [ms]
r1787 CO: Output of Xm-adaption / Outp. Xm-adaption
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [%] Data set: -
% 100 <=>
0305p3
0304p
I 3
V
Z
N
N
N
=
=
Rated motor impedance: