SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Displays control word 2 received from Fieldbus.
Description: Selects up to 3 faults or warnings for non-default reactions.
Example: If, for example, an OFF3 is to be carried out instead of an OFF2 for a fault, the fault number has to be entered in
P2100 and the desired reaction selected in P2101 (in this case (OFF3) P2101 = 3).
Index: [0] = Fault Number 1
[1] = Fault Number 2
[2] = Fault Number 3
Note: All fault codes have a default reaction to OFF2.
Some fault codes caused by hardware trips (e.g. overcurrent) cannot be changed from the default reactions.
Description: Sets drive stop reaction values for fault selected by P2100 (alarm number stop reaction).
This indexed parameter specifies the special reaction to the faults/warnings defined in P2100 indices 0 to 2.
Values: 0: No reaction, no display
1: OFF1 stop reaction
2: OFF2 stop reaction
3: OFF3 stop reaction
4: No reaction warning only
Index: [0] = Stop reaction value 1
[1] = Stop reaction value 2
[2] = Stop reaction value 3
Note: Settings 1 - 3 are only available for fault codes.
Setting 4 is only available for warnings.
Index 0 (P2101) refers to fault/warning in index 0 (P2100).
r2091.0...15 BO: Control word 2 from Fieldbus / CtrlWd2 <- FB
CU240S DP
CU240S DP-F
CU240S PN
Access level: 3 P-Group: Communications Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fixed frequency Bit 0 Yes No -
01 Fixed frequency Bit 1 Yes No -
02 Fixed frequency Bit 2 Yes No -
03 Fixed frequency Bit 3 Yes No -
04 Drive Dataset (DDS) Bit 0 Yes No -
05 Drive Dataset (DDS) Bit 1 Yes No -
08 Enable PID Yes No -
09 Enable DC brake Yes No -
11 Enable Droop Yes No -
12 Torque control Yes No -
13 External fault 1 No Yes -
15 Command Dataset (CDS) Bit 1 Yes No -
p2100[0...2] Alarm number selection / Alarm No selection
Access level: 3 P-Group: Messages Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
0 65535 0
p2101[0...2] Stop reaction value / Stop reaction val.
Access level: 3 P-Group: Messages Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
0 4 0