EasyManua.ls Logo

Siemens Sinamics G120 Series - p2850 Delay time of timer 1; Delay time timer 1; p2851 Mode timer 1; Mode timer 1; r2852.0 BO: Timer 1; Timer 1; r2853.0 BO: Nout timer 1; Nout timer 1

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-268
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines delay time of timer 1.
P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Dependency: P2802[0] is active level for the timer.
Description: Selects mode of timer 1.
P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Values: 0: ON delay (seconds)
1: OFF delay (seconds)
2: ON/OFF delay (seconds)
3: Pulse generator (seconds)
10: ON delay (minutes)
11: OFF delay (minutes)
12: ON/OFF delay (minutes)
13: Pulse generator (minutes)
Dependency: P2802[0] is active level for the timer.
Description: Displays output of timer 1.
P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Dependency: P2802[0] is active level for the timer.
Description: Displays Not-output of timer 1.
P2849, P2850, P2851 are the inputs of the timer, outputs are P2852, P2853.
Dependency: P2802[0] is active level for the timer.
p2850 Delay time of timer 1 / Delay time timer 1
Access level: 3 P-Group: Technology Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
0.0 [s] 9999.9 [s] 0.0 [s]
p2851 Mode timer 1 / Mode timer 1
Access level: 3 P-Group: Technology Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
0 13 0
r2852.0 BO: Timer 1 / Timer 1
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -
r2853.0 BO: Nout timer 1 / Nout timer 1
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -