Parameters
List of Parameters
1-270
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Displays Not-output of timer 2
P2854, P2855, P2856 are the inputs of the timer, outputs are P2857, P2858.
Dependency: P2802[1] is active level for the timer.
Description: Define input signal of timer 3.
P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency: P2802[2] is active level for the timer.
Description: Defines delay time of timer 3.
P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Dependency: P2802[2] is active level for the timer.
Description: Selects mode of timer 3.
P2859, P2860, P2861 are the inputs of the timer, outputs are P2862, P2863.
Values: 0: ON delay (seconds)
1: OFF delay (seconds)
2: ON/OFF delay (seconds)
3: Pulse generator (seconds)
10: ON delay (minutes)
11: OFF delay (minutes)
12: ON/OFF delay (minutes)
13: Pulse generator (minutes)
Dependency: P2802[2] is active level for the timer.
r2858.0 BO: Nout timer 2 / Nout timer 2
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -
p2859 BI: Timer 3 / Timer 3
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0
p2860 Delay time of timer 3 / Delay time timer 3
Access level: 3 P-Group: Technology Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
0.0 [s] 9999.9 [s] 0.0 [s]
p2861 Mode timer 3 / Mode timer 3
Access level: 3 P-Group: Technology Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
0 13 0