Parameters
List of Parameters
1-276
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Define inputs of Divider 2, result is in P2884.
Index: [0] = Connector input 0 (CI 0)
[1] = Connector input 1 (CI 1)
Dependency: P2802[11] is active level for the Divider.
Description: Result of Divider 2.
Dependency: P2802[11] is active level for the Divider.
Description: Defines inputs of Comparator 1, output is P2886.
Index: [0] = Connector input 0 (CI 0)
[1] = Connector input 1 (CI 1)
Dependency: P2802[12] is active level for the Comparator.
Description: Displays result bit of Comparator 1.
Dependency: P2802[12] is active level for the Comparator.
p2883[0...1] CI: DIV 2 / DIV 2
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 755[0]
r2884 CO: DIV 2 / DIV 2
Access level: 3 P-Group: Technology Data type: Floating Point
Unit: [%] Data set: -
p2885[0...1] CI: CMP 1 / CMP 1
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 755[0]
P2885
r2886
x1
x2
Out
x1
x2
Out = 1
x1 < x2
Out = 0
P2800
P2802[12]
Out = x1 x2
CMP
Index0
Index1
r2886.0 BO: CMP 1 / CMP 1
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -