Siemens Sinamics G120 Series - p9799 SI parameter checksum; SI checksum; p9801 SI enable parameter; SI enable param.; p9802 SI enable safe brake monitoring; SI brake mon. ena; p9803 SI Selection of Safety Source; SI Source select

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-294
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Confirm checksum of the P1 safety parameters. The correct value has to be entered before leaving the safety com-
missioning with p3900 = 10.
Only if r9798, r9898, p9799 and p9899 are all identical, the commissioning can be finished.
Note: Enter the reading of r9798 or r9898 into p9799 once no more safety parameters need to be changed.
Description: Double of parameter p9601. See there.
Note: On non-safety hardware units, p9801 is zero by default.
Description: Double of parameter p9602. See there.
Values: 0: Disable monitoring of safe brake control
1: Enable monitoring of safe brake control
Description: Double of parameter p9603. See there.
p9799 SI parameter checksum / SI checksum
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0000 hex FFFF hex 8AFD hex
p9801 SI enable parameter / SI enable param.
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
- - 0010 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 reserved Yes No -
01 Enable forced dynamisation (self test) after
STO
Yes No -
p9802 SI enable safe brake monitoring / SI brake mon. ena
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0 1 0
p9803 SI Selection of Safety Source / SI Source select
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
07 STO, SS1, SLS activated via PROFIsafe Yes No -