Function diagrams
Internal Setpoint Source
2-336
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Fig. 2-15 3100 – Motor Potentiometer (MOP)
- 3100 -
Function diagram
87654321
3100_MOP.vsd
Internal Setpoint Source
SINAMICS G120
02.04.2007 V3.0
Motor Potentiometer (MOP)
0 1
1 0
1 1
0 0
-1
0
1
MOP output start value control
MOP
RFG
(0)
Setp. auto/manu
P1041.CDS
MOP setpoint
-650.00 ... 650.00 [Hz]
P1040.DDS (5.00)
Max. frequency
0.00 ... 650.00 [Hz]
P1082.DDS (50.00)
r1050
MOP outp.freq. [Hz]
(19.13)
Enable MOP(UP)
P1035.CDS
(19.14)
Enable MOP(DWN)
P1036.CDS
MOP mode
- ... -
P1031.DDS (0)
Inhib. MOP reverse
0 ... 1
P1032 (1)
1
0
MOP auto setpoint
(0)
P1042.CDS
(0)
MOP acc RFG setpo
P1043.CDS
MOP RFG setpoint
(0)
P1044.CDS
MOP ramp-up time
0.00 ... 1000.00 [s]
P1047.DDS (10.00)
MOP rampdown time
0.00 ... 1000.00 [s]
P1048.DDS (10.00)
r1045
MOP RFG input [Hz]
Bit 00 = 1: Setpoint store active
Bit 01 = 1: No On-state for MOP necessary