Parameters
List of Parameters
1-52
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Specifies third flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
The saturation characteristic is defined using 4 points (P0362 - P0365, P0366 - P0369). This parameter specifies
the y coordinate (flux) for the third value pair of the characteristic.
Dependency: The following applies for the flux values: P0362 < P0363 < P0364 < P0365, otherwise a linear characteristic is
applied internally.
Note: P0364 = 100 % corresponds to rated motor flux.
Rated flux = rated EMF
Description: Specifies fourth flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
The saturation characteristic is defined using 4 points (P0362 - P0365, P0366 - P0369). This parameter specifies
the y coordinate (flux) for the fourth value pair of the characteristic.
Dependency: The following applies for the flux values: P0362 < P0363 < P0364 < P0365, otherwise a linear characteristic is
applied internally.
Note: P0365 = 100 % corresponds to rated motor flux.
Rated flux = rated EMF
Description: Specifies first magnetizing current value of the saturation characteristic in [%] relative to the rated magnetizing cur-
rent (P0331).
The saturation characteristic is defined using 4 points (P0362 - P0365, P0366 - P0369). This parameter specifies
the x coordinate (magnetizing current) for the first value pair of the characteristic.
Dependency: Affects P0320 (motor magnetizing current).
The following applies for the magnetizing currents: P0366 < P0367 < P0368 < P0369, otherwise a linear character-
istic is applied internally.
p0364[0...2] Magnetizing curve flux 3 / Magnet.curve flux3
Access level: 4 P-Group: Motor Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
20.0 [%] 200.0 [%] 115.0 [%]
p0365[0...2] Magnetizing curve flux 4 / Magnet.curve flux4
Access level: 4 P-Group: Motor Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
20.0 [%] 200.0 [%] 125.0 [%]
p0366[0...2] Magnetizing curve imag 1 / Magnet.curve imag1
Access level: 4 P-Group: Motor Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
20.0 [%] 250.0 [%] 50.0 [%]