EasyManua.ls Logo

Siemens Sinamics G120 Series - r0372[0...2] Cable resistance [%]; Cable res. [%]; r0373[0...2] Rated stator resistance [%]; Rated stat.res.[%]; r0374[0...2] Rotor resistance [%]; Rotor res. [%]; r0376[0...2] Rated rotor resistance [%]; Rated rot. res.[%]

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-54
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Displays standardized cable resistance of motor equivalent circuit (phase value)in [%].
It is estimated to be 20 % of the stator resistance.
Description: Displays rated stator resistance of the motor equivalent circuit (phase value) in [%].
Description: Displays standardized rotor resistance of the motor equivalent circuit (phase value) in [%].
Description: Displays rated rotor resistance of the motor equivalent circuit (phase value) in [%].
Description: Displays standardized total leakage reactance of the motor equivalent circuit (phase value) in [%].
Note:
If an output filter is selected the inductance of the filter (p0233) is added to the leakage inductance
(the value is not stored in p0233 for Siemens filters).
Description: Displays standardized main reactance of the motor equivalent circuit (phase value) in [%].
Description: Displays calculated rotor time constant [ms].
Description: Displays total leakage time constant of motor.
r0372[0...2] Cable resistance [%] / Cable res. [%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
r0373[0...2] Rated stator resistance [%] / Rated stat.res.[%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
r0374[0...2] Rotor resistance [%] / Rotor res. [%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
r0376[0...2] Rated rotor resistance [%] / Rated rot. res.[%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
r0377[0...2] Total leakage reactance [%] / Tot.leak.react.[%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
% 100 <=>
p03053
p0304
I 3
N
V
N
=
=
Z
N
=
ph
V
ph
I
Rated motor impedance:
r0382[0...2] Main reactance [%] / Main reactance [%]
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: DDS
r0384[0...2] Rotor time constant / Rotor time const.
Access level: 3 P-Group: Motor Data type: Floating Point
Unit: [ms] Data set: DDS
r0386[0...2] Total leakage time constant / Total leak. Tconst
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [ms] Data set: DDS

Table of Contents