EasyManua.ls Logo

Siemens SINAMICS G120 - Page 164

Siemens SINAMICS G120
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
8.12 dv/dt filter plus VPL
Power Module PM240-2
162 Hardware Installation Manual, 01/2020, A5E33294624B AL
Article number JTA: TEF1203
-0KB
-0LB
-0MB
Rated power
90 kW
132 kW
250 kW
Rated voltage (phase to phase)
690 V (+10%)
690 V (+10%)
690 V (+10%)
Rated output current (rms)
103 A
230 A
416 A
Maximum output current (rms)
160 A
70 A
104 A
Inductance (Tolerance ± 5%)
0.53 mH
0.37 mH
0.22 mH
Winding resistance
3 x 4.9 mΩ
3 x 3.25 mΩ
3 x 1.4 mΩ
Nominal pulse frequency
2 kHz
2 kHz
2 kHz
Maximum pulse frequency
4 kHz
4 kHz
4 kHz
Output current maximum pulse fre-
quency
61.8 A
87.6 A
156 A
Maximum output frequency
150 Hz
150 Hz
150 Hz
Voltage drop
17.2 V
17.1 V
18.0 V
Rated DC link voltage
935 V
935 V
935 V
Maximum voltage rise at motor ter-
minals
1)
< 500 V/μs
< 500 V/μs
< 500 V/μs
Maximum peak voltage at motor
terminals (phase to phase)
2) 3)
1350 V ... 1500 V
1350 V ... 1500 V
1350 V ... 1500 V
Maximum peak voltage at motor
terminals (phase to earth)
2)
1100 V
1100 V
1100 V
Maximum cable length filter - motor
(screened / unscreened)
3)
450 m / 650 m
525 m / 800 m
450 m / 650 m
525 m / 800 m
450 m / 650 m
525 m / 800 m
Terminal type
Busbar M8
Busbar M10
Busbar M10
Rated terminal cross section (load
circuit)
95 mm²
120 mm²
2x120 mm²
1x185 mm²
Rated terminal cross section (DC
link feedback)
4)
25 mm²
25 mm²
50 mm²
Degree of protection
5)
IP00
IP00
IP00
Ambient temperature
6)
-20°C to 40°C
-20°C to 40°C
-20°C to 40°C
Weight
77 kg
97 kg
172 kg
Connection
Metrical (mm² / Nm)
Imperial (AWG / lbf.in)
Line / motor cable
95 / 13.0
3/0 / 115
120 / 13.0
4/0 / 115
2 x 120 / 13.0
2 x 4/0 / 115
185 / 13.0
6/0 / 13.0
DC link
25 / 9.0
4 / 80
25 / 9.0
4 / 80
50 / 9.0
1 / 80
Ground
50 / 6.0
1 / 53
70 / 6.0
2/0 / 53
95 / 6.0
3/0 / 53
1)
Voltage rise according IEC/TS 60034-17
2)
Under nominal DC link voltage
3)
Maximum peak voltage at motor terminals < 1350V at cable length up to 450m screened or 650m unscreened Maximum
peak voltage at motor terminals < 1500V at cable length up to 525m screened or 800m unscreened
4)
Short-circuit-proof wiring is required
5)
Installing the filter in an enclosure is required
6)
Higher ambient temperatures up to 60°C allowed with current derating at 40°C, in the range 4050°C with 1.5% per 1K
and in the range 5060°C with 1.9% per 1K