Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
380 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Table 12- 5 PM230, IP20, Frame Sizes B, 3 AC 380 V … 480 V
Order No. - without filter
Order No. - with filter
LO power
LO input current
4 kW
10.5 A
5.5 kW
13.6 A
7.5 kW
18.6 A
HO power
HO input current
3 kW
8.0 A
4 kW
10.5 A
5.5 kW
13.6 A
Fuse according to IEC
3NE1 813-0
3NE1 814-0
3NE1 815-0
Required cooling air flow
Cross section of line and motor cables 1.5 … 6 mm
2
1.5 … 6 mm
2
1.5 … 6 mm
2
Tightening torque for line and motor cables
Weight, unfiltered
2.8 kg
2.8 kg
2.8 kg
Table 12- 6 PM230, PT, Frame Sizes B, 3 AC 380 V … 480 V
Order No. - without filter
Order No. - with filter
LO power
LO input current
7.5 kW
18.6 A
HO power
HO input current
5.5 kW
13.6 A
Fuse according to IEC
3NE1 815-0
Required cooling air flow
Cross section of line and motor cables 1.5 … 6 mm
2
Tightening torque for line and motor cables
Weight, unfiltered
3.4 kg