EasyManua.ls Logo

Siemens SINAMICS G120 - Page 380

Siemens SINAMICS G120
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
380 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Table 12- 5 PM230, IP20, Frame Sizes B, 3 AC 380 V … 480 V
Order No. - without filter
Order No. - with filter
6SL3210…
6SL3210…
…1NE21-0UL0
…1NE21-0AL0
…1NE21-3UL0
…1NE21-3AL0
…1NE21-8UL0
…1NE21-8AL0
LO power
LO input current
LO output current
4 kW
10.5 A
10.2 A
5.5 kW
13.6 A
13.2 A
7.5 kW
18.6 A
18 A
HO power
HO input current
HO output current
3 kW
8.0 A
7.7 A
4 kW
10.5 A
10.2 A
5.5 kW
13.6 A
13.2 A
Fuse according to IEC
Fuse according to UL
3NE1 813-0
AJT15 / 3NE1 813-0
3NE1 814-0
AJT20 / 3NE1 814-0
3NE1 815-0
AJT25 / 3NE1 815-0
Power loss
0.12 kW
0.15 kW
0.22 kW
Required cooling air flow
9.2 l/s
9.2 l/s
9.2 l/s
Cross section of line and motor cables 1.56 mm
2
16 … 10 AWG
1.56 mm
2
16 … 10 AWG
1.56 mm
2
16 … 10 AWG
Tightening torque for line and motor cables
0.6 Nm / 5 lbf in
0.6 Nm / 5 lbf in
0.6 Nm / 5 lbf in
Weight, unfiltered
Weight, filtered
2.8 kg
3 kg
2.8 kg
3 kg
2.8 kg
3 kg
Table 12- 6 PM230, PT, Frame Sizes B, 3 AC 380 V … 480 V
Order No. - without filter
Order No. - with filter
6SL3211…
6SL3211…
…1NE21-8UL0
…1NE21-8AL0
LO power
LO input current
LO output current
7.5 kW
18.6 A
18 A
HO power
HO input current
HO output current
5.5 kW
13.6 A
13.2 A
Fuse according to IEC
Fuse according to UL
3NE1 815-0
AJT25 / 3NE1 815-0
Power loss
0.22 kW
Required cooling air flow
9.2 l/s
Cross section of line and motor cables 1.56 mm
2
16 … 10 AWG
Tightening torque for line and motor cables
0.6 Nm / 5 lbf in
Weight, unfiltered
Weight, filtered
3.4 kg
3.6 kg