Service and maintenance
5.2 Replacing components
Power Module PM240
54 Hardware Installation Manual, 07/2009, A5E00807525B AD
Cooling fan replacement for FSD … FSF
Preparatory steps
Power-down the inverter
Remove the Control Unit from the inverter
Disconnect all the cables from the Power Module
Place the Power Module face-down on a clean and safe surface
Removal
1. Remove the fan retaining board
2. Release the fan cable connectors
3. Remove the cooling fan out from the inverter
Figure 5-2 Cooling fan removal FSD and FSE (15 kW … 37 kW)
Figure 5-3 Cooling fan removal FSF (45 kW … 110 kW)
Installation
For re-installation, carry out the above steps in reverse order.