SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
515
2 Parameters
2.2 List of parameters
Description: Setting parameter for the run sequence of instance NCM 0 within the run-time group set in p20316.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NCM 1 of the numeric comparator.
Index: [0] = Input X0
[1] = Input X1
Description: Display parameter for binary quantity QU of instance NCM 1 of the numeric comparator.
QU is only set if X0 > X1.
Description: Display parameter for binary quantity QE of instance NCM 1 of the numeric comparator.
QE is only set if X0 = X1.
Description: Display parameter for binary quantity QL of instance NCM 1 of the numeric comparator.
QL is only set if X0 < X1.
p20317 NCM 0 run sequence / NCM 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
0 32000 820
p20318[0...1] CI: NCM 1 inputs / NCM 1 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
- - 0
r20319 BO: NCM 1 output QU / NCM 1 output QU
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
- - -
r20320 BO: NCM 1 output QE / NCM 1 output QE
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
- - -
r20321 BO: NCM 1 output QL / NCM 1 output QL
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
- - -